msd Mini-Scleral Design (from Blanchard CL company)

  • designed to vault the cornea and fit on the sclera/conjunctiva, reducing the net-vault of the contact lens over the cornea
  • reduction in the chance of irritation and better centering
  • keratoconus fits that dont center or dislodge with eye mvmt
  • irregular cornea fits
  • GP-intollerant patients (chronic awareness)
  • sagital depth of the CL
  • trial fit progressively deeper vaults until corneal clearance achieved
  • compression ring on conjunctiva after full day wear is ok
  • if mid-peripheral or limpal touch exists, increase the mid-peripheral zone of the lens to move the surface of the lens off the cornea
  • if mid-peripheral space b/w lens and cornea is too great (causing an air bubble), which may cause epithelial desiccation, decreasing the mid-peripheral zone will minimize these issues
  • small air bubbles in periphery that move during lens wear don't interfere with vision or cause epithelial surface drying